2 drive failure management, 1 global and local spare drive – Asus PCI-DA2200 User Manual

Page 15

Advertising
background image

3-5

ASUS PCI-DA2200 User’s Manual

RAID 5

Striping with
Interspersed Parity









RAID 5 is similar to RAID 3 but the parity data is not stored in one
dedicated hard drive. Parity information is interspersed across the
drive array. In the event of a failure, the controller can
recover/regenerate the lost data of the failed drive from the other
surviving drives.

3.2 Drive Failure Management

3.2.1 Global and Local Spare Drive

Local Spare Drive is a standby drive
assigned to serve one specified logical
drive. When a member drive of this
specified logical drive fails, the Local
Spare Drive becomes a member drive and
automatically starts to rebuild.

Global Spare Drive does not only serve one specified logical drive.
When a member drive from any of the logical drive fails, the Global

Block 1

Block 2

Block 3

Block 4

Block 5

Block 6

Block 7

Block 8

.
.

Logical Drive

Physical Disks

Block 1

Parity (3,4)

Block 6

Block 7

Block 2

Block 3

Parity (5,6)

Block 8

Parity (1,2)

Block 4

Block 5

Parity (7,8)

.
.

.
.

.
.

Striping + non-dedicated Parity

Logical Drive

Local Spare Drive

1

2

3

LS

Assigns one Local Spare

Drive to a logical drive

Logical Drive

1

2

3

X

LS

Local

Spare

Drive

When one member
drive fails, the Local
Spare Drive joins the
logical drive and
automatically starts
to rebuild.

RAID 5

Minimum
Disks required

3

Capacity

N-1

Redundancy

Yes

Advertising