Rebuild, Automatic rebuild – Asus PCI-DA2200 User Manual

Page 19

Advertising
background image

3-9

ASUS PCI-DA2200 User’s Manual

Rebuild

Automatic Rebuild

One member drive

fails in logical drive

Any

local spare drive

assigned to logical

drive?

Any

global spare drive

assigned to logical

drive?

“Periodic

Auto-Detect Failure

Drive Swap Check Time”

enabled?

Has the

failed drive been

swapped?

Waiting for spare

drive to be added
or manual rebuild

Rebuild using the

swapped drive

Rebuild using the

local spare drive

Rebuild using the

global spare drive

Keep detecting if drive
has been swapped or

spare drive has been

added

No

Yes

No

No

Yes

No

Yes

Yes

When a member drive in the logical drive failed, the controller will
first check whether there is a Local Spare Drive assigned to this
logical drive. If yes, it will automatically start to rebuild.

If there is no Local Spare Drive available, the controller will search
for a Global Spare Drive. If there is a Global Spare Drive, it will
automatically rebuild the logical drive.

If neither a Local Spare Drive nor a Global Spare Drive is available,
and the “Periodic Auto-Detect Failure Drive Swap Check Time” is
“Disabled,” the controller will not try to rebuild unless the user
applies a forced manual rebuild.

When the “Periodic Auto-Detect Failure Drive Swap Check Time” is
enabled (i.e., a check time interval has been selected), the controller
will detect whether or not the failed drive has been swapped (by
checking the failed drive’s channel/ID). Once the failed drive has
been swapped, the rebuild will begin immediately.