Asus PCI-DA2200 User Manual

Page 20

Advertising
background image

3-10

ASUS PCI-DA2200 User’s Manual

If the failed drive is not swapped but a local spare drive is added to
the logical drive, rebuilding will begin with the spare drive.

Manual Rebuild

When a user applies forced-manual rebuild, the controller will first
check whether there is any Local Spare Drive assigned to this logical
drive. If yes, it will automatically start to rebuild.

If there is no Local Spare Drive available, the controller will search
for a Global Spare Drive. If there is a Global Spare Drive, it will
automatically rebuild the logical drive.

User applies

forced-manual

rebuild

Any

Local Spare Drive

assigned to this

logical drive?

Yes

Yes

Rebuild using the

Local Spare Drive

Any

Global Spare Drive

assigned to this

logical drive?

Rebuild using the

Global Spare Drive

No

No

Wait for

manual rebuild

Yes

Has the failed drive

been replaced?

Rebuild using the

replaced drive

No

If neither a Local Spare Drive nor a Global Spare Drive is available,
the controller will detect the SCSI channel and ID of the failed drive.
Once the failed drive has been replaced by a new drive/used drive, it
starts to rebuild using the replaced drive. If there is no available
drive for rebuilding, the controller will not try to rebuild again until
the user applies another forced-manual rebuild.

Advertising