3-20

ASUS PCI-DA2200 User’s Manual

controller communicates with the SAF-TE enclosure with standard
SCSI commands, polling the device in order to get SAF-TE
information.

The default value for “Periodic SAF-TE Device Check Time” is
“Disabled”. If the enclosure does have a SAF-TE device and features,
enable the controller to poll the device by selecting a time interval.
The RAID controller will then check the SAF-TE device status at that
interval.

SAF-TE Support

Drive Status

Indicators

UPS Failure
Signal Input

Power Supply

Failure

Signal Input

Cooling Fan

Failure

Signal Input

Temperature Alert

Signal Input

SAF-TE

Chipset

PCI-to-SCSI

Text RAID Manager

error alert

GUI RAID Manager

error alert

The SAF-TE chipset connects to the drive channel of the
controller together with the other SCSI drives.

System with

RAID controller

installed

3.5.8 Periodic Auto-Detect Failure Drive

Swap Check Time

The “Drive-Swap Check Time” is the interval at which the controller
checks to see whether a failed drive has been swapped. When a
logical drive’s member drive fails, the controller will detect the failed
drive (at the selected time interval). Once the failed drive has been
swapped with a drive that has adequate capacity to rebuild the
logical drive, the rebuild will begin automatically.

The default setting is “Disabled,” meaning that that the controller
will not Auto-Detect the swap of a failed drive. To enable this
feature, select a time interval.

Advertising