Asus PCI-DA2200 User Manual

Page 262

Advertising
background image

ASUS GUI RAID Manager: Array Management

4.5 Setting Controller Configuration

4-11

4.5 Setting Controller

Configuration

The GUI RAID Manager enables you to modify the
configuration of the disk array controller from your manager
console. You can enable or disable the write-back cache of the
system, set whether or not the controller will reset the SCSI bus
during power-on, stagger the drives’ motor spin-up sequence, set
the baud rate of the controller’s RS-232 port, and modify the
station password.

The following describes the user-configurable parameters:

Write-Back. This parameter allows you to enable or

disable the write-back cache of the system. The write-
back cache allows write data to be stored in the cache
memory prior to writing to the disk, thereby pipelining the
I/O write process.

SCSI Reset on Power-up. This parameter determines

whether or not the controller will assert SCSI bus reset
during power-on initialization.

Staggered Drive Spin-Up. This parameter determines

whether or not the controller will sequence the drives to
start spinning in succession at five-second intervals.
Enabling staggered drive spin-up can help prevent
overloading the power supply when many drives spin up at
the same time.

RS-232 Baud Rate. This parameter sets the baud rate of

the RS-232 port on the controller. When connecting a host
computer, terminal, or other device (such as a modem)
onto this port, ensure that their baud rates are set
accordingly; otherwise, there will be communication
problems.

Advertising