Xylem IM116 R04 4 Submersible Pumps User Manual

Page 36

Advertising
background image

36

GENERACIÓN II - DE 2-HILOS, 4 PULG. DATOS

ELÉCTRICOS LA MONOFÁSICO, 60 HERTZ, 3450 RPM

GENERACIÓN II - DE 3-HILOS, 4 PULG. DATOS

ELÉCTRICOS LA MONOFÁSICO, 60 HERTZ, 3450 RPM

Carga plena Factor de servicio Amperaje

del rotor

bloqueado

Winding

Resis-

tance

Có-

digo

kVA

Tipo CP No. de

orden

HP

kW Voltios SF Amps Watts Amps Watts

PSC

de

2-

hilos

M05421

0.5 0.37 115 1.6

7.9

910

9.8

1120

28

1.4-2.0

H

M05422

0.5 0.37 230 1.6

4.0

845

4.7

1050

16

6.1-7.2

J

M07422

0.75 0.55 230 1.5

5.0

1130

6.2

1400

18

5.9-6.9

F

M10422

1.0 0.75 230 1.4

6.7

1500

8.1

1800

24

4.2-5.2

F

M15422

1.5

1.1

230 1.3

9.0

2000

10.4

2350

43

1.8-2.4

H

Carga plena Factor de servicio Ampe-

raje del

rotor blo-

queado

Winding

Resistance

Caja de

control

requerida

1

Tipo CP No.

de orden HP kW Voltios SF

Amps Watts Amps Watts

Prin-

ciple

(B-Y)

Ar-

ranque

(R-Y)

3-hilos

con

Q.D.

rectán-

gulo

del

co-

mienzo

del con-

densa-

dor

M05411 0.5 0.37 115 1.6

Y – 8.8

B – 8.8

R – 0

675

Y – 10.9

B – 10.9

R – 0

980

44

1.0-

1.4

2.5-

3.1

CB05411

M05412 0.5 0.37

230

1.6

Y – 5.3

B – 5.3

R – 0

740

Y – 6.1

B – 6.1

R – 0

1050

21

5.1-

6.1

12.4-

13.7

CB05412

M07412 0.75 0.55

1.5

Y – 6.6

B – 6.6

R – 0

970

Y – 7.8

B – 7.8

R – 0

1350

32

2.6-

3.3

10.4-

11.7

CB07412

M10412 1.0 0.75

1.4

Y – 8.1

B – 8.1

R – 0

1215

Y – 9.4

B – 9.4

R – 0

1620

41

2.0-

2.6

9.3-

10.4

CB10412

3-hilos

con

CSCR

(CR)

o el

rectán-

gulo de

control

magné-

tico del

contac-

tor

(MC)

M05412 0.5 0.37

1.6

Y – 4.2

B – 4.1

R – 1.8

715

Y – 4.8

B – 4.3

R – 1.8

960

21

1.0-

1.4

2.5-

3.1

CB05412CR

M07412 0.75 0.55

1.5

Y – 4.8

B – 4.4

R – 2.5

940

Y – 6.0

B – 4.9

R – 2.3

1270

32

5.1-

6.1

12.4-

13.7 CB07412CR

M10412 1.0 0.75

1.4

Y – 6.1

B – 5.2

R – 2.7

1165

Y – 7.3

B – 5.8

R – 2.6

1540

41

2.6-

3.3

10.4-

11.7 CB10412CR

M15412 1.5 1.1

1.3

Y – 9.1

B – 8.2

R – 1.2

1660

Y – 10.9

B – 9.4

R – 1.1

2130

49

2.0-

2.6

9.3-

10.4

CB15412CR o

CB15412MC

M20412 2

1.5

1.25

Y – 9.9

B – 9.1

R – 2.6

2170

Y – 12.2

B – 11.7

R – 2.6

2660

49

1.6-

2.2

10.8-

12.0

CB20412CR o

CB20412MC

M30412 3

2.2

1.15

Y – 14.3

B – 12.0

R – 5.7

3170

Y – 16.5

B – 13.9

R – 5.6

3620

76

1.1-

1.4

2.0-

2.5

CB30412CR o

CB30412MC

M50412 5

3.7

1.15

Y – 24.0

B – 19.1

R – 10.2

5300

Y – 27.0

B – 22.0

R – 10.0

6030

101

.62-

.76

1.36-

1.66

CB50412CR o

CB50412MC

¹ Un rectángulo de control de CSCR con un sufijo del CR se puede substituir por una conclusión magnética del modelo del contactor en MC.

Advertising