APPENDIX C

DS-4483 Lookup Tables



The DS-4483 supports a single lookup table for use in calculating derived data from an attached sensor.
This format is identical to that used by HydroTel 2000™.

The lookup table must be contained in a text file with a .tbl extension and only integer values are
permitted. The format of the table is that of ‘paired couplets’. An excerpt of a sample table is shown
below:

1000

Recorded value from attached physical sensor

21600

Value to be inserted for derived sensor

1010

Recorded value from attached physical sensor

22000

Value to be inserted for derived sensor

1020

22300

1030

22600

1040

22900

1050

23200

1060

23600


The DS-4483 deals with recorded values that fall between table entries by using simple linear
interpolation. Thus for the table above, if a value of 1005 is recorded, the associated derived value will be
calculated as:

21600

+ (22000 – 21600) * (1005 – 1000) =

21800

(1010

1000)


Table Size


The DS-4483 will support tables ranging from 2 couplets up to 512 couplets.