3.1.1 AWAY arming/External activation

External activation arms ALL detectors integrated in the system. Use this type of
activation only if there is nobody in the object and you too are leaving the object.

To activate externally:

1. Check the READY LED and make sure that the system can be activated.

2. Enter your user PIN and press

. All partitions assigned to this PIN are now

activated.

IMPORTANT:

If programmed (-> Installer menu ->Quick Arm), you can arm your system simply by

pressing the active key

. You do not have to enter your user PIN.

3. Leave the object and close the door. The operating panel beeps and the ACTIVE

LED flashes. The system changes to exit delay mode. If the countdown of the exit
delay time has started, the following message is played: "System in arm process,
please exit now!
".???

4. After the exit delay time expires, the ACTIVE LED lights permanently and the

following message is announced: “System armed in away”

IMPORTANT:

If you cannot arm the system because a zone is open, you hear this voice message:
System not ready, fail to arm, check Zone X.
Close the respective zones and arm the system again.

If you cannot arm the system due to any other problem, you hear this voice message:
System not ready, fail to arm, check display.
Check the system faults and remove the reason for the fault. Then rearm the system.