Atec Tektronix-1502 User Manual

Page 12

Advertising
background image

TM 9-4935-601-14-3&P

Table 1-2. (cont)

ELECTRICAL CHARACTERISTICS

Characteristics

Performance Requirements

Supplemental Information

FEET/DIV Control
At X.1 Multiplier
Range

To 20 feet/div
To 5 metres/div for metric

Scales

.1 feet/div to 20 feet/div

8 steps, 1-2-5 sequence

0.025 m/div to 5 m/div for metric

8 steps, 1-2.5-5 sequence

At X1 Multiplier
Range

To 200 feet/div

DISTANCE dial disabled in

To 50 metres/div for metric

200 (FIND) position

Scales

1 foot/div to 200 feet/div

8 steps, 1-2-5 sequence

0.25 m/div to 50 m/div for metric

8 steps, 1-2-5 sequence

Dielectric Scales

SOLID PTFE, V

p

/V

air

, = 0.70

r

= 2.04

SOLID POLY, V

p

/V

air

= 0.66

r

= 2.31

OTHER-VAR, V

p

/V

air

, = 0.55 to 1

VAR is calibrated for air
when turned to full cw
position. All buttons re-
leased causes default mode
and is cal. for air

Accuracy

Within ±2%

External Recorder Inter-
face for X-Y Recorders
Horizontal

0.1 V/div

Source impedance 10 k

Vertical

0.09 to 0.13 V/div (adjustable)

Source impedance 10 k

Pen Lift
Mode 1
Source

V

s

= 5 V Nominal with R

s

= 10 k

Mode 2 (inverted
Mode 1)
Source

V

s

= 5 V Nominal with R

s

= 10 k

Y-T Plug-in Chart Recorder
Interface
Horizontal

0.4 V/div

Source impedance 200

(switched)

Vertical

0.2 V/div

Source impedance 200

(switched)

The TEKTRONIX Chart Recorder,
016-0506-03 is designed to operate
with the 1502. The chart uses
a heat sensitive stylus to
record on 4 cm chart paper.
Chart recording length is con-
trolled by the 1502.

REV D JAN 1981

1-3