Figure 5-8 – Atec Tektronix-1502 User Manual

Page 65

Advertising
background image

TM 9-4935-601-14-3&P

NOTE

1. Pressing the retainer should cause some of the sealant to appear outside the retainer area, see Fig. 5-7.

Failure of the sealant to appear at any point around the retainer is an indication of inadequate sealing.

2. When performing this step, assure that the shield makes flush contact with the subpanel, see Fig. 5-7.

5. After a curing time of approximately 4 hours, use a small wooden dowel, such as a Q-tip handle, and

remove the excess sealant that is visible between the shield and retainer.

8. Preparation of Front Panel for assembly (see Fig. 5-8)

a. FRONT PANEL MPL Item 2-47.

b. Procedure

1. Clean mating surface of front panel with acetone.

2. Coat mating surface of panel with No. 1204 primer. Allow 2 hours curing time.

9. Bonding of Plug-in Compartment seal to Front Panel (see Fig. 5-9)

a. SEAL, PLUG-IN MPL Item 2-48

b. Procedure

1. Clean mating surfaces of seal with acetone.

2. Apply No. 3144 sealant to mating surface of seal.

3. Position seal on rear side of Front Panel.

Figure 5-8. Front Panel, Identification of Parts For Assembly Step 8 Through 26.