Figure 5-35, Figure 5-34, Figure 5-36 – Atec Tektronix-1502 User Manual

Page 74

Advertising
background image

TM 9-4935-601-14-3&P

Figure 5-34. Lubrication of FOCUS and INTENSITY
control knobs.

2. Install the knobs on the shafts of the FOCUS and INTENSITY controls.

30. Watertight sealing procedures for the Battery Pack (see Figs. 5-35 and 5-36)

a. BATTERY PACK MPL Item 2-37.
b. PANEL Not shown in MPL.
c. HEAT SINKS Not shown in MPL.
d. GASKET Not shown in MPL.
e. Procedure

1. Clean Panel with isopropyl alcohol.
2. Form a bead of No. 3144 sealant in and around each of the six screw holes in the Panel. See Fig. 5-

35.

3. Apply a film of Dow Corning No. 4. Compound to the mating surfaces of the heat sinks and the Panel

and join as shown in Fig. 5-36.

4. Clean the gasket with acetone.
5. Apply a bead of G-661 silicone grease on and around the gasket and attach it to the Panel as shown

in Fig. 5-36.

31. Watertight sealing procedures for the Front Panel jacks of the X-Y Output Module, 016-0606-00 (see
Fig. 5-37)

a. FRONT PANEL MPL Item 3-13.
b. SUB PANEL MPL Item 3-14.
c. JACK, TIP: BLACK MPL Item 3-5.

Figure 5-36. Application of dielectric type compound.

@ FEB 1980

5-18

Figure 5-35. Sealing of Battery Pack screwholes

Advertising