MoTeC M8 User Manual

Page 41

Advertising
background image

MoTeC

Initial Starting Procedure

39

The Injector Current Setup Parameter IJCU is set too high.

The battery voltage is too low.

Over Duty

The injector duty cycle is too high, typically the duty cycle should not exceed
85%.

If the injectors exceed their maximum duty then larger injectors or higher fuel
pressure is needed.

REF / SYNC Errors

The possible causes of the various errors are detailed below :

REF Error

Too many REF pulses have occurred between SYNC pulses.

Possible causes :

A bad REF signal has caused extra pulses or a SYNC pulse has
been missed - check voltage levels with a scope.

Bad REF / SYNC alignment.

Incorrect Setup

No REF

Two SYNC signals have occurred without a REF signal.

Possible causes :

If the RPM is 0 then there is no signal - check the wiring and sensor
voltage levels with a scope.

If RPM is not 0 then a bad SYNC signal has caused extra pulses -
check voltage levels with a scope.

If RPM is low then the REF and SYNC signals may have been
swapped.

Incorrect Setup

SYNC Error

The SYNC signal has occurred before expected.

Possible causes :

A bad SYNC signal has caused extra SYNC pulses - check voltage
levels with a scope.

Advertising