Injector errors, Over duty, Ref / sync errors – MoTeC M84 User Manual

Page 43: Ref error, No ref

Advertising
background image

MoTeC

Initial Starting Procedure

41

Injector Errors

Open

The Injector is open circuit - check the wiring.

Short

The Injector is short circuit - check the wiring.

Peak

The Injector peak current was not reached.

Possible causes:
• The Injector Current Setup Parameter IJCU is set too high.
• The battery voltage is too low.

Over Duty

The injector duty cycle is too high, typically the duty cycle should not exceed
85%.

If the injectors exceed their maximum duty then larger injectors or higher fuel
pressure is needed.

REF / SYNC Errors

The possible causes of the various errors are detailed below:

REF Error

Too many REF pulses have occurred between SYNC pulses.

Possible causes:
• A bad REF signal has caused extra pulses or a SYNC pulse has

been missed - check voltage levels with a scope

• Bad REF / SYNC alignment
• Incorrect

Setup

No REF

Two SYNC signals have occurred without a REF signal.

Possible causes:
• If the RPM is 0 then there is no signal - check the wiring and sensor

voltage levels with a scope.

• If RPM is not 0 then a bad SYNC signal has caused extra pulses -

check voltage levels with a scope.

• If RPM is low the REF and SYNC signals may have been swapped.
• Incorrect

Setup

Advertising