Sync error, No sync, Multiple ref / sync errors – MoTeC M84 User Manual

Page 44: 42 initial starting procedure motec

Advertising
background image

42

Initial Starting Procedure

MoTeC

SYNC Error

The SYNC signal has occurred before expected.

Possible causes:
• A bad SYNC signal has caused extra SYNC pulses - check voltage

levels with a scope.

• A bad REF signal has caused missing REF pulses - check voltage

levels with a scope.

• Bad REF / SYNC alignment.
• Incorrect

Setup

No SYNC

Two or more consecutive SYNC pulses are missing.

Possible causes:
• No SYNC signal - check the wiring and SYNC sensor voltage levels

with a scope.

• A bad REF signal has caused many extra pulses - check voltage

levels with a scope.

• Incorrect

Setup

Multiple REF / SYNC Errors

Multiple REF / SYNC errors may occur. Often the first error to occur is
the correct error.

Multiple errors may also occur due to incorrect Setup.

Advertising