Selecting the Adjust Table

Once a file or the ECU has been opened, the appropriate table or setup
screen may be selected from the Adjust menu by using the mouse or the
keyboard.

To select the Adjust menu using the keyboard hold down the Alt key followed
by the A key then use the arrow keys and the Enter key to make a selection.

Alternatively, the Adjust menu may be displayed by pressing the Esc key.
This has the advantage that it shows the Adjust menu with the current table
selected, which often makes it easier to select the next table.

Fuel / Ignition Toggle (F5 key)

The F5 key will quickly toggle the screen between the current Fuel table and
the corresponding Ignition table or vice versa.

F6, F7, F8 Key Assignment

The F6, F7 or F8 keys may be assigned to any table by pressing Alt+F6,
Alt+F7 or Alt+F8. This assigns the current table to the F6, F7 or F8 keys
which allows that table to be returned to quickly.

Changing Table Values

Selecting the Item to be Adjusted

The cursor selects the table value that may be adjusted.