Appendix J: CAN Wiring - Multiple Devices

The CAN bus should consist of a twisted pair trunk with 100R (0.25Watt)
terminating resistors at each end of the trunk.

The preferred cable for the trunk is 100R Data Cable but twisted 22# Tefzel is
usually OK.

The maximum length of the bus is 16m (50ft) including the MoTeC CAN Cable
(PC to CAN Bus Communications Cable)

CAN Devices (such as MoTeC ADL, BR2 etc.) may be connected to the trunk
with up to 500mm (20in) of twisted wire.

The connector for the CAN Communications Cable may also be connected to
the trunk with up to 500mm (20in) of twisted wire and should be within 500mm
of one end of the trunk. If desired, two CAN Cable connectors may be used so
that the MoTeC CAN Cable may be connected to either side of the vehicle.
Both connectors must be within 500mm of each end of the trunk.

Short CAN Bus

If the CAN Bus is less than 2m (7ft) long then a single termination resistor
may be used. The resistor should be placed at the opposite end of the CAN
Bus to the CAN Cable connector.

Single Device

See Appendix K: CAN Bus Wiring - Single Device.