• COMMUNICATION PORTS:

REMOTE RS232

Connector:

DB 9 female

Level: RS232.

Data Rate:

9600 Bauds, 8 data bits, 1 stop bit, no parity bit,

no flow control for normal. DTR & RTS needed

for

upgrade.

• GP-I/O:

Connector:

8 pin MCO male connector

Rating:

0.5A @ 125VAC - 2A @ 30VDC (contact closure).

Functions:

Tally

• LAN:

Connector:

RJ45

Protocol:

TCP (Transmission Control Protocol) or UDP

(User Datagram Protocol).

Ethernet:

Base 10/100

• DVI (Digital Video Interface) OUTPUTS:

Connector:

Outputs #1 (Main) & #2 (Preview): Female DVI-I.

Signal:

Digital Visual Interface (DVI)-TMDS single link.

Resolutions:

Format

Ratio

Refresh Rate

HDTV 720p

16 : 9

50Hz 59,94Hz 60Hz

HDTV 1035i

16 : 9

59,94Hz 60Hz

HDTV 1080i

16 : 9

50Hz 59,94Hz 60Hz

HDTV 1080p

16 : 9

23,97Hz 24Hz 25Hz 29,97Hz 30Hz

HDTV 1080sF

16 : 9

50Hz 59,94Hz 60Hz

640 x 480

4 : 3

50Hz 60Hz 72Hz 75Hz

800 x 600

4 : 3

50Hz 60Hz 72Hz 75Hz

848 x 480

16 : 9

50Hz 60Hz 72Hz 75Hz

1024 x 768

4 : 3

50Hz 60Hz 72Hz 75Hz

1280 x 720

16 : 9

50Hz 60Hz

1280 x 768

15 : 9

50Hz 60Hz 72Hz 75Hz

1280 x 800

16 : 10

50Hz 60Hz 72Hz 75Hz

1280 x 1024

5 : 4

50Hz 60Hz 72Hz 75Hz

1360 x 768

16 : 9

50Hz 60Hz 72Hz 75Hz

1366 x 800

15 : 9

50Hz 60Hz 72Hz 75Hz

1400 x 1050

4 : 3

50Hz 60Hz 72Hz 75Hz

1440 x 900

16 : 10

50Hz 60Hz 72Hz 75Hz

1600 x 1200

4 : 3

50Hz 60Hz

1680 x 1050

16 : 10

50Hz 60Hz

1920 x 1080

16 : 9

50Hz 60Hz

1920 x 1200

16 : 10

50Hz 60Hz

2048 x 1080

19 : 10

50Hz 60Hz

Communication specifications