• SETUP DEVICE SYNC CABLE

• CHECK DEVICE SYNC OPERATION

• FOLLOW SETUP

• READY TO OPERATE

Device Sync

Device Sync

Complete straight cable (8 wires)

Once all the devices booted and connected to the remote controller, you should setup a show with 3 devices (for

our example) on the same screen. If the device sync function is correctly operated, the 3 devices must show:

For accurate synchronisation, output rate must be set to «framelock» on the same reference for all the devices.

Use Genlock connector or common input as reference.

NB: make sure that other inputs that follows the reference are set «RefSync»

on the input menu (ie. 3 genlocked cameras)

--[DEVICE SYNCHRO]--
Pos: 1 Count: 3

Master

Communication OK

--[DEVICE SYNCHRO]--
Pos: 2 Count: 3

Slave

Communication OK

--[DEVICE SYNCHRO]--
Pos: 3 Count: 3

Slave

Communication OK

Extended
EDID
RefSync
Status

NB: devices will activate device sync functionnality only in multi machine mixer mode (with screen count greater than1).

Devices will not sync if:

- The device sync cable is not connected as above.
- Two or more devices have the same «screen position».
- One of the «Count» devices is missing.
- Version of all devices is not at least v5.00.