Analog Way Di-VentiX II User Manual

Page 74

Advertising
background image

14. If during the black level adjustments, thin white columns

appear on the left and right edges of the overlapping area,

you can correct them by adjusting the Left and Right areas in

the “Softedge” – “Black Levels” – “Left-Right Area” menu.

15. In the “Soft Edge” – “Test Pattern” menu, select the “H Grey

Scale” pattern if you are in Horizontal Softedge or the “V Grey

Scale” pattern if you are in Vertical Softedge.

16. In the “Softedge” menu, activate the “Blending” menu.

17. In the “Softedge” – “Curves” menu, adjust the Softedge Curve

with the “X1, Y1, X2, Y2” adjustments, so that the luminance

of the projection becomes uniform throughout the projection

area (entire screen).

18. When the adjustment becomes quite good, switch off the test

pattern and display your background source to do any fine

tuning if needed.

Result is:

BLACK LEVEL

adjustment

Luma

level

Luma

level

Light Gray

Light Gray

Border Effects

Gone

Border Effects

Black

Black

Screen

Screen

BLACK LEVEL

adjustment limited area

Covering Area

72