3- TIPS
•
Front panel Di-VentiX II status:
«Due to HDCP content, non-HDCP screens cannot display protected sources»
This message is displayed on the menu when a input content (HDCP sources) is detected and when not all
of the DVI output screens are HDCP.
For example,
a DVI output not connected to a screen, this is considered as a non HDCP screen.
• How to have a non HDCP Di-VentiX II:
When it is known that non protected content will be displayed, the user can disable the output HDCP detec-
tion with the front panel menu or control command (version 5.00 minimum).
• To avoidHDCP cabling problems, when quality allows it, prefer an analog YUV input signal.
• DVI plugs must be used to have a good electrical contact.
WARNING: DVI cables are fragile and must not be bent or folded.
75