Connecting motor xtuc s11, Introduction, Tools instruction – FlexLink XT (макс. 30 кг) Монтаж User Manual
Page 19
Advertising

5113235 19
Connecting motor XTUC S11
Introduction
NOTE! The capacitor must always be encapsulated to
prevent electric shock.
Tools
Instruction
-
-
1 Connect the motor according to wiring diagram
below.
Bro
wn (No 2) On S8R25GE g
re
y)
Bro
wn (No 2) On S8R25GE g
re
y)
Green/yellow
GND
Green/yellow
GND
Capacitor
Capacitor
1
2
Neutral
Phase
Neutral
Phase
3
4
50
, 230V
Hz
60Hz,115V
Forward
Forward
Reverse
Reverse
Speed
m/min
Speed
m/min
5
4
10
15
20
M
M
6
12
18
M
M
3
3
4
3
4
4
3
2
1
1
2
1
2
Blac
k (No 3)
White
(No
1)
Blac
k (No 3)
White
(No
1)
Green/Y
ellow (No 4)
Black (No 3)
White (No 1)
Grey (No 2)
Phase
Neutral
T/P
Capacitor
Green/Y
ellow (No 4)
Black (No 3)
White (No 1)
Grey (No 2)
Phase
Neutral
T/P
Capacitor
M
M
M
M
M
M
GND
GND
Advertising