Mounting lift and locate module xtul p12 – FlexLink XT (макс. 30 кг) Монтаж User Manual
Page 70

70
5113235
Mounting lift and locate module XTUL P12
Introduction
If nothing else is specified this instruction step is valid
for all mounting options (F00, F01 and F02).
CAUTION! Running this module without enclosure
can cause personal injury.
Tools
Instruction
Allen key
4 mm
Allen key
5 mm
Allen key
6 mm
Box wrench
19 mm
Box wrench
24 mm
1 If F=F00
Place the unit on your attachment device and
tighten the four M8 screws using a 5 mm Allen
key.
NOTE! The horizontal plane on the attachment
device and the plane on the conveyor chains
must be parallel.
2 If F=F01
Insert the four M6 slot nuts into the conveyor T-
slot. Mount the support frame onto the conveyor
and tighten the four M6 screws using a 4 mm
Allen key.
The upper holes on the brackets are for mounting
the support frame onto an XT Compact
conveyor.
M8 (4×)
Attachment device