Appendix b, Service monitoring, Initial measuring data – FlexLink YOUTILIZE User Manual

Page 114: Providing production efficiency, Appendix b service monitoring

Advertising
background image

Providing production efficiency

Page 114 of 125

Appendix B

Service Monitoring

The following describes what needs to be done for every conveyor in the system.

Initial measuring data

Gap, chain-beam, top (Gap_top)

The initial (nominal) value must be measured by a service engineer at start up or change of the
component.

• Measure_Nominal

Gap_top

Thickness of chain top (Chain_top)

The initial (nominal) value must be measured by a service engineer at start up or change of the
component.

• Measure_Nominal

Chain_top

Gap, chain-side plate, idler end (Gap_idler)

The initial (nominal) value must be measured by a service engineer at start up or change of the
component.

• Measure_Nominal

Gap_idler

Thickness of tab (Chain_tab)

Formatted: Danish