Providing production efficiency

Page 121 of 125

SI(Ah)

Starting point,
[Y

0

;X

0

]

Inspection point,
[Y

1

;X

1

]

Estimated lifetime (SI),
[Y

Lim

;X

Lim

]

Wear (mm)

Picture 5: Graph SI(Ah) vs wear(mm)

The starting point is called [Y

0

;X

0

]. This is the time when a new component is installed. Both the

Service Index (Y

0

) and the wear (X

0

) is zero because the conveyor has not been run at all yet. When

an inspection is done we have an actual wear value of the component, X

1

. The corresponding

accumulated SI value is called Y

1

.

With this set the estimation of the Service Index for the component can be calculated.

x

*

X

Y

f(x)

Y

SI

1

1

=

=

=

Estimated Lifetime in Service Index, SI

lim

(Ah)

If we use this formula we can estimate the point where the wear is reaching its limit value. The limit
value of the wear is called X

Lim

and the corresponding Service Index Y

Lim

. There are four wear

measures and one SI

limit

connected to each one.