Flowline LI90 Commander User Manual

Page 56

Advertising
background image

56 of 57

PRELIMINARY MANUAL

27 AUG 08

Commander LI90 Series

Rev 1_3

Using Removable Media to Log Data

• The Commander has the feature of logging data to a Micro SD card in the form of

comma-delimited files, with a .CSV extension. These files are compatible with
standard database and spreadsheet PC programs.

• To activate the data log in the commander, press and hold the Left Arrow (shown above)

for 10 seconds. When Data Log Activated appears, release the button. The unit will log
the four analog inputs at rate of once per 15 seconds.

• When completed, follow the previous instructions for removing the Micro SD card.
• The data in the card will appear in five folders. Folder A_Inputs contains the raw and

scaled data for the four analog inputs (see chart below).

Channel 1

Channel 2

Channel 3

Channel 4

Data Folder

A_Inputs A_Inputs A_Inputs A_Inputs

Raw analog input

(referenced between

0 to 32,000 units)

%AI0001 %AI0002 %AI0003 %AI0004

Scaled input

(referenced between

Empty and Full settings)

%R0107 %R0207 %R0307 %R0407

• Folders AI1_Set, AI2_Set, AI3_Set and AI4_Set contain the configuration information

for the analog inputs (see below).

Channel 1

Channel 2

Channel 3

Channel 4

Data Folder

AI1_Set AI2_Set AI3_Set AI4_Set

Sensor Max. Range

%R0123 %R0223 %R0323 %R0423

Sensor Dead Band

%R0125 %R0225 %R0325 %R0425

Sensor Height

%R0133 %R0233 %R0333 %R0433

Sensor Fill_H

%R0135 %R0235 %R0335 %R0435

Empty Setting

%R0103 %R0203 %R0303 %R0403

Full Setting

%R0105 %R0205 %R0305 %R0405