Important installation information – Controlled Products Systems Group H10NX User Manual
Page 15
Advertising

VIKING TECHNICAL SUPPORT 1.800.908.0884
1 3
!
CAUTION: To Reduce the Risk of Fire or Injury to Persons:
!
WARNING: For use with gates at a maximum 2200 lbs. in weight or 75 ft. in length.
IMPORTANT INSTALLATION INFORMATION
2200 lb.
75 ft
Locate Control Buttons:
1. Within sight of the gate,
2. At a minimum height of 5 feet
so small children are not able to
reach it; and
3. At least 6 feet away from all
moving parts of the gate.
Specifications
Maximum Gate Length:
75 ft.
Maximum Gate Weight:
2200 lb.
Operating Temperature:
-20ºF (-28ºC) to 158ºF (70ºC)
Power
Requirements:
115v / 230v AC (4 amp / 2 amp)
Single Phase (50 Hz / 60 Hz)
DO NOT allow pedestrian use of this gate