Appendix (a), Access control connections, Power connections – Controlled Products Systems Group H10NX User Manual

Page 44: Technical tip, Terminals connections and input functions

Advertising
background image

VIKING TECHNICAL SUPPORT 1.800.908.0884

4 2

Access Control Connections

Appendix (A)

Power Connections

The control board provides a 24v DC output to power external devices and controls.
Alternatively, for devices that require a power supply other than 24v DC, the
operators Power Box contains a convenient 120v AC receptacle to connect a plug-in
transformer.

“C”

=

Common

“N.O.”

=

Normally Open

!

TECHNICAL TIP:

Each input Terminal (i.e. Radio, Exit, Re-Open, UL) has a corresponding

Status LED that when illuminated indicates an input is currently being provided to the
terminal and the gate is responding accordingly. (See pages 36-37 LED References)

Terminals Connections and Input Functions:

Viking

Terminal

Function

Device

Terminal

“+28v” --------------------- DC Positive ---------------

+

“GND” --------------------- DC Negative ---------------

“GND” --------------------- Relay Common --------------- “C”
“Radio” -------------------------------------------------------------

“N.O.”

If “Timer” OFF:

Open - Stop - Close

If “Timer” ON:

Open / Stop while closing

“UL” (see pages 10 & 11)

“N.O.”

If Input is brief:

Stops gate then Reverses 12 inches

If input is longer:

Stops gate, does not reverse

“Re-Open”

“N.O.”

If stopped:

No function

If closing:

Stops then Opens gate

“ATG” Anti-Tailgate

“N.O.”

Input is received:

Stops gate if closing

Input is released:

Closes gate to prevent tailgating

“C.

Loop”

“N.O.”

If not at open limit:

No function

If at open limit:

Prevents gate from Closing

“Open”,

“Exit”,

“Fire”

&

“Strike”

“N.O.”

If stopped:

Opens gate

If closing:

Stops then Opens gate

“Stop” “N.O.”

If traveling:

Stops gate

“Close”

“N.O.”

If stopped:

Closes gate

If traveling:

No function

“Radio” -------------------------------------------------------------

“N.O.”

“UL” (see pages 10 & 11)

“N.O.”

“Re-Open”

“N.O.”

“ATG” Anti-Tailgate

“N.O.”

“C.

Loop”

“N.O.”

“Open”,

“Exit”,

“Fire”

&

“Strike”

“N.O.”

“Stop” “N.O.”

“Close”

“N.O.”

Advertising