TROUBLESHOOTING

Call out LCD Display, Diag-

nose Button and Diag-
nose LED

LCD MSG

Meaning

Page 41

TS Ref #s

VIKING
ACCESS

Welcome Message

MODEL
H10

Indicates the Model of the unit

System Status Messages

GATE IS
IDLE

Gate is stopped between limits

GATE IS
OPENING

Gate is opening

GATE IS
CLOSING

Gate is closing

GATE IS
OPENED

Gate is at the limit open position

GATE IS
CLOSED

Gate is at the limit close position

STOP BY
OBSTRUCT

Gate stopped due to an obstruction sensor event

11, 12,
13

STOP BY
OVERLOAD

Gate stopped due to an overload of the gate system

11, 12

OVERLAP
TIMING

Gate is waiting for the overlap time

HOLDING
__ SEC

Gate is at the limit open position and timing to close - The display shows
the actual time left - prior to time-out

EPS2
OK

Electronic Positioning Sensor is functioning properly. Will also provide an
error percentage while the motor is running

LCD Display References

The control board is equipped with a LCD Display that provides operator information,
current conditions, settings, diagnostics and error messages. Use the table below to
identify the corresponding “TS Ref#” and refer to page 41 for further troubleshooting.