Troubleshooting, Lcd msg, Multi meter displays – Controlled Products Systems Group H10NX User Manual

Page 41: Board settings messages, Lcd display references, Meaning

Advertising
background image

VIKING TECHNICAL SUPPORT 1.800.908.0884

3 9

TROUBLESHOOTING

LCD Display References

LCD MSG

Meaning

Page 41

TS Ref #s

Multi Meter Displays

MOT AMP
__._ A

This is the motor current amperage during operation

MOT VOLT
__._ VDC

This is the actual motor voltage during operation

AC VOLT
__._ VAC

This is the actual low voltage AC to the Control Board from the transformer

CHARGE
__._ VDC

This is the charging voltage to the batteries

BAT VOLT
__._ VDC

This is the charging voltage when Battery Switch is OFF or the battery
voltage when the low voltage AC is discontinued to the Control Board

Board Settings Messages

EPS2
___% ERR

Indicates that the Electronic Positioning Sensor (EPS) needs to be tuned.
Error rate is displayed as a percentage

Speed
xx%

Shows the percentage of speed set by the Speed adjustment on the control
board. (pg. 24)

OVERLAP
_._ SEC

Shows the number of seconds set by the Overlap Adjustment on the con-
trol board.

This feature is not available on slide gate operator models

ODS SENS
___%

Shows the amount of force required to trip the obstruction sensor. (pg. 26)

TIMER
__ SEC

Shows the time delay to hold the gate open at the limit open position,
before starts closing the gate. (pg. 24)

HEATER
__ OFF

The Integrated Heater is disabled for the open

“OPN”

and/or close

“CLS”

limits (pg. 27)

HEATER
__ ON

The Integrated Heater has been enabled to turn on at the open

“OPN”

and/

or close

“CLS”

limits (pg. 27)

“*”

will be displayed while it is heating

LOCK MOD
OFF

The Lock Mode feature is turned OFF (pg. 27)

LOCK MOD
ON

The Lock Mode feature is turned ON (pg. 27)

Advertising