Chapter 6 qwcm – Pach and Company Quantum QC Series Manual User Manual

Page 39

Advertising
background image

Table of Contents

file:///C|/PACH%20&%20COMPANY/PACH-CO.COM/PACH-CO.COM%202012/online_manual/qc_series_manual.htm[5/19/2014 9:40:29 AM]

1.

The system must be install in

Intercom and Call Forwarding Mode Wiring Diagram

or

Call Forwarding Mode

wiring Diagram

2.

Function code 38

must be set at least for 1 ring

3.

Function code 39

must be set to 1

4. You must have the system phone number
5. Call the system phone number if the system answered, short beep will be heard.
6. Press # then 4-digit Master code (default is 0000), short beep will be heard if master code is accepted
7. Press * to establish two ways communication
8. Press 9 to release relay 1 (door 1) or 8 to release relay 2 (door 2).

CHAPTER 6

QWCM Internet IP Module

The QWCM is only applicable for QR5IP. Click

here

for complete manual for QWCM

QR5

IP

DEFAULT SETTING

IP: 192.168.1.230
SUBNET: 255.255.255.0
GATEWAY: 192.168.1.1

DNS: 192.168.1.1
USERNAME: Administrator
PASSWORD: 8888