Fulton Thermal Corp.*Electric Thermal Fluid Heaters Manual* Version 2010-0423

Page 101

650°F and shall be supplied complete with motor starter for proper motor HP, voltage and

cycles.

8. Tests

a) Shall include a hydrostatic test of the pressure vessel in the presence of an inspector

having a National Board Commission. He shall certify a Data Report which shall be

delivered with the heater as evidence of ASME Code compliance. In addition to ASME

symbol, the heater shall bear a National Board Registration Number.

b) Full electrical checks will be performed including testing of all controls and circuitry.

9. Operating Manual

a) Instructions for installation, operation, and maintenance of the heat transfer system shall

be contained in a manual provided with each unit.

b) A complete wiring diagram, corresponding to the equipment supplied, shall be part of the

manual and one shall also be affixed to the inside of the heater’s panel box.