Installation, Ransburg – Ransburg Vector Solo 79901 Waterborne RS90-WB User Manual

Page 17

Advertising
background image

Vector Solo Waterborne Applicators - Installation

INSTALLATION

13

Ransburg

†

Typical installations to spray non-flamma-

ble conductive materials (waterborne mate-

rials) must not be used to handle flammable

materials (solvent based materials). Refer

to the "Introduction" section for definition of

water-based and solvent-based materials.

W A R N I N G

!

WATERBORNE

ISOLATION SYSTEM

INSTALLATION

GUIDELINES

Using waterborne coating with electrostatic equip-

ment requires that the fluid source be isolated from

ground. Precautions should be taken to ensure

operator safety and system efficiency.

The following guidelines should be followed:

• The fluid lines and source MUST be isolated

from ground. an isolating paint stand or similar

isolating (non-porous) material MUST be used.

†

Never use wood products, wooden

boxes, pallets, or boards as an isolator.

wood contains moisture and is a poor in-

sulator. Electrical current passing through

these materials can ignite them, causing a

hazardous condition.

C A U T I O N

!

Isolation stands MUST be at least 45.7 cm

(18 inches) from grounded booth walls,

chain link fences, or other grounded objects.

Air hoses to the pressure pot or pump on the

insulating stand should be non-conductive

plastic. Many rubber hoses will have static

grounding circuits or carbon content and are

NOT suitable for this application.

All charged (isolated) systems MUST be

inside a fence or cage to prevent contact by

personnel. An interlock system MUST be

provided that interrupts high voltage flow to

the applicator if the gate is opened.

Air regulators for pots or pumps should be

mounted remotely outside the fence or cage

area to facilitate changes in pressure without

shutting the system down.

Grounding hooks at the cage MUST be used

to ground the system when personnel are

working close by.

Fluid lines to the applicator MUST be pro-

tected from scraping and abrasion on the

floor or sharp metal edges that could lead

to voltage pin holing and loss of kV on the

charged system.

Cleanliness and maintenance are extremely

critical.

Refer to "Installation - 79901 RS90 Water-

borne Installation" in the "Installation" sec-

tion of this manual.

AH-08-03.6

Advertising