Waterborne hose fitting installation, Ransburg – Ransburg Vector Solo 79901 Waterborne RS90-WB User Manual

Page 18

Advertising
background image

Vector Solo Waterborne Applicators - Installation

14

Ransburg

Air Hose

†

For proper safe function of the applica-

tor, the 79727-XX Air Hose must be used

(either standard or quick disconnect style).

W A R N I N G

!

Fluid Hose Recommendation

Ransburg recommends using either a 3/16" ID

(79524) or an 1/4" ID (79525) Fluid Hose As-

sembly. This assembly is made to specifically fit

the applicator. This hose is available from your

authorized Ransburg distributor. Available hose

lengths are listed in "Accessories" in the "Parts

Identification" section of this manual.

†

Any user installed fluid hose used must

be rated for 6.9 bar (100 psig) working pres-

sure minimum.

C A U T I O N

!

WATERBORNE HOSE

FITTING INSTALLATION

For 79901 RS90 Solo - Waterborne: Ransburg

supplies the waterborne fluid hose factory pre-as-

sembled to the applicator unit. Standard hose

lengths are 10m, 15m, 20m, and 30m. To modify

the hose length, use the following procedures.

All adjustments must be made at the supply end

of the system.

1. Remove the male connector and swivel fitting

from the end of the fluid hose by turning the nut

of the male connector counter-clockwise while

holding its main body.

2. Remove the male connector nut from the fluid

hose.

3. Determine the hose length that is needed and

cut the hose off squarely.

4. Carefully score the outer jacket linearly and then

radially approximately 45.7 cm (18-inches) back

from the cut end. Split the outer jacket along the

linear score mark and peel it away from the inner

sheath. Then remove the jacket completely by

tearing along the radial score mark.

†

Special care must be taken when re-

moving the sheathing from the fluid hose.

Make sure all tools are very sharp and only

score the surface of the sheath. Inserting

the knife too deep can score the surface of

the core material and lead to pin-holing and

failure of the hose.

W A R N I N G

!

5. Lightly score the inner sheath linearly and then

radially 1-inch from the outer jacket. Split the in-

ner sheath along the linear score mark and peel

it away from the core fluid hose. Then remove

the sheath completely by tearing along the radial

score mark.

6. Roll the inner sheath back over itself until it

touches the outer jacket.

7. Cut approximately 1/4-inch of inner sheath off.

AH-08-03.6