Vector Solo Waterborne Applicators - Maintenance

27

Ransburg

1. Remove applicator from the worksite after

following the "Flush Procedure".

2. Remove fluid hose from the applicator.

Figure 21: Remove Fluid Hose

Figure 22: Clockwise to Remove Air Hose

AIR CAP

Removal

1. While holding the barrel with one hand, loosen

the retaining nut using the other hand.

2. Unscrew the retaining nut completely and

remove the air cap.

Figure 23: Air Cap Removal

Cleaning and Inspection

1. Use a suitable solvent to clean the air cap.

(Refer to "Suitable Solvents for Cleaning Vector

Solo Applicators" in the "Maintenance" section.)

2. Examine the air cap for damage to the air

horns, face, and any air passages. If any of these

areas are damaged or worn, the air cap should

be replaced.

Reinstall

1. Check the fluid nozzle to ensure that it is tightly

screwed into the barrel.

2. Place the air cap over the electrode wire of the

needle/electrode and set it onto the fluid nozzle.

3. Place the retaining nut over the air cap and

begin screwing it onto the barrel.

4. Before securing the retainer nut to the barrel,

position the air cap for the desired spray pattern.

†

Ensure all pressure has been bled from

the fluid and air line prior to disconnection.

W A R N I N G

!

3. Remove air hose at base of applicator.

C W

C W

C C W

AH-08-03.6