Vector Solo Waterborne Applicators - Maintenance
39
Ransburg
3. Install the 1/4 module into the 3/4 module and
tighten the two (2) screws.
Figure 66: Module Assembly
4. Install power module to handle and tighten
three (3) screws. Reinstall the fluid hose.
3. Remove the 1/4 module from the 3/4 module.
Pull the fluid fitting out.
Figure 63: Fluid Fitting Removal
2. Install the fluid fitting.
Figure 65: Fluid Fitting Replacement
Figure 64: Ground Clip Replacement
Fitting Replacement
1. Ensure the ground clip is properly installed.
Tabs must be touching the air and fluid fitting.
Figure 67: Power Module Assembly
The ground clip must be properly in-
stalled such that it touches both the air and
fluid fitting.