Test and maintenance kit usage (79870-00), Ransburg, Vector solo waterborne applicators - maintenance – Ransburg Vector Solo 79901 Waterborne RS90-WB User Manual

Page 44

Advertising
background image

Vector Solo Waterborne Applicators - Maintenance

40

Ransburg

TEST AND

MAINTENANCE KIT

USAGE (79870-00)

Figure 68: 79870 Test and Maintenance Kit

3

6

5

2

4

1

The 79870 Test and Maintenance Kit allows the

user to determine the inlet pressure at the base

(handle) of the Vector Solo hand-held applicators.

The Test and Maintenance Kit also allows the user

to test the 79835 Power Module Assembly on the

Vector Solo applicator.

The procedure to test the inlet pressure at the

base (handle) of the Vector Solo applicator is as

follows (see Figures 63 and 64):

1. Connect the left-hand fitting of the 79727 Air

Hose to the male inlet of the Test and Maintenance

Kit.

2. Connect the 6" air hose assembly [3] between

the brass tee fitting and the gun air inlet.

3. Connect the other end of the air hose to the

regulated air supply.

4. Turn on main air. Trigger the applicator with kV

switch on high (down position). Read the pressure

at the 100 psi pressure gauge. This pressure should

be at least 2.75bar (40 psi) with air flowing for

proper functioning of the Vector Solo applicator.

Figure 69: Testing the Pressure at the Base

(Handle) of the Applicator

1

2

3

4

5

6

79870 TEST AND

MAINTENANCE KIT

Item#

Brass Tee Fitting

100 psi Pressure Gauge

6" Air Hose Assembly

Left Hand Male Fitting

Barb Fitting

Tubing

Description

AH-08-03.6

Advertising