Installation, Ransburg – Ransburg Vector Solo 79901 Waterborne RS90-WB User Manual

Page 20

Advertising
background image

Vector Solo Waterborne Applicators - Installation

16

Ransburg

INSTALLATION

The following assemblies are available for

purchase:

†

The air hose ground must be connected

to true earth ground.

W A R N I N G

!

Interlocks Required

Interlock the solvent supply with the main supply

air to the applicator. If solvents with a flashpoint

below the normal ambient temperature of the spray

booth are used, the interlock must be installed.

When solvent is On, main supply air to the appli-

cator is Off. Interlocks are user supplied.

†

The solvent supply must be interlocked

with applicator supply air.

†

If solvents with a flash point below the

normal ambient temperature of the spray

booth are used, the interlock must be in-

stalled.

W A R N I N G

!

79525-10 Fluid Hose Assembly, 1/4" ID X 10m long
79525-15 Fluid Hose Assembly, 1/4" ID X 15m long
79525-20 Fluid Hose Assembly, 1/4" ID X 20m long
79525-25 Fluid Hose Assembly, 1/4" ID X 25m long
79525-30 Fluid Hose Assembly, 1/4" ID X 30m long
79524-10 Fluid Hose Assembly, 3/16" ID X 10m long
79524-15 Fluid Hose Assembly, 3/16" ID X 15m long
79524-20 Fluid Hose Assembly, 3/16" ID X 20m long
79524-25 Fluid Hose Assembly, 3/16" ID X 25m long
79524-30 Fluid Hose Assembly, 3/16" ID X 30m long

WATERBORNE HOSE

ASSEMBLIES

Part #

Description

In order to use a waterborne hose, the Conductive

Fluid Conversion Kit (79891-00) must be used

as well.

Figure 3: Conductive Fluid Conversion Kit

1. Ensure there is a true earth ground connection

available.

In order for the waterborne hose assembly to

work properly, it must be correctly installed onto

a current Vector Solo applicator. The following

steps describe how to install a waterborne hose

onto a Vector Solo.

Figure 4: Voltage Off Lever Position

(Bottom View)

2. Isolate the fluid source from true earth ground.

3. Ensure electrostatic On/Off lever is in the Off

position.

4. Connect the air hose ground wire to true earth

ground.

5. Connect the air hose to the applicator,

thread

is left hand pitch, counter-clockwise to tighten.

AH-08-03.6

†

It is the end users responsibility to insure

the ground end of the 79727-XX air hose is

connected to true earth ground.

W A R N I N G

!

Advertising