Rma-303 indirect charge - introduction – Ransburg RMA Indirect A12869 User Manual

Page 17

Advertising
background image

RMA-303 Indirect Charge - Introduction

LN-9268-11.4

12

Mechanical (Cont.)

Maximum Angular Velocity
for Turbine (Robot Motion):

250

°

/sec.


Shaping Air #1 (SAI)
Supply:

Variable (See "Pressure Flow Data Charts" in this section.)


Shaping Air #2 (SAO)
Supply:

Variable

(See "Pressure Flow Data Carts" in this section.)


Brake Air Supply:

60-100 psig

(Nominal):

(414-689 kPa)


Maximum Fluid Pressure Supply:

Paint:

200 psi (1379 kPa)

Solvent:

150 psi (1035 kPa)


Fluid Flow Rate:

25-700 cc/min.


Bell Cup Cleaning Time
(Internal/External):

2-7 sec. (Approx.)


Color Change Time:

Dependent on system configuration, fluid pressures, fluid vis-

cosity, fluid line lengths, etc.


Speed Readout:

Magnetic pick-up, unidi-rectional fiber optic transmission


Bell Cup Replacement
Time:

Less than 2 minutes


Minimum Control Equipment
Requirements:
Versions listed or higher)
MicroPak

LECU5004-17 (V3.84)

Atomizer Module

A11925-00 (V 0.4)

I/O Module

A11435-00 (V1.4) (0-10V) (4-20 mA)

Specifications and ratings based on testing at sea level standard conditions.

Tubing Bundle Max. 450

°

Rotation in either Direction.

Advertising