Rma-303 indirect charge - installation, Air filtration requirements – Ransburg RMA Indirect A12869 User Manual

Page 38

Advertising
background image

RMA-303 Indirect Charge - Installation

33

LN-9268-11.4

Ransburg Filter
Model No.

Description / Specifications

Replacement Ele-
ment Part No.

HAF-503

Pre-filter, removes coarse amounts of oil, moisture
and dirt. Used upstream of HAF-508 pre-filter
(used in systems with poor air quality.

HAF-15 Element One

HAF-508

Pre-filter, coalescing type, 136 SCFM, 98.5% effi-
ciency particulate removal .3 to .6 micron, max.
aerosol passed 1.0 micron, max. solid passed .4
micron (dependent upon SCFM requirement per
applicator, one HAF-508 can be used with up to
three RMA-303 assemblies).

HAF-38 Elements,
Carton of 4

RPM-418

Bearing air filter, coalescing type,19 SCFM,
99.995% efficiency particulate removal .3 to .6 mi-
cron, max. RMA-303 passed .6 micron max. solid
passed .2 micron (one per RMA-303

)

RPM-33 Elements,
Carton of 8

AIR FILTRATION REQUIREMENTS

N O T E

Volume Booster Recommendation (Turbine
Air):

Ransburg Part # A11111-00

Pilot Operated Regulator Non-Bleed Pilot

SCFM-200

Supply - 300 P.S.I.

Temperature Range: 40˚ - 120° F

>

Each applicator must have its own

filter for bearing air. Recommended:
RPM-418 or equivalent