Rma-303 indirect charge - maintenance – Ransburg RMA Indirect A12869 User Manual

Page 74

Advertising
background image

RMA-303 Indirect Charge - Maintenance

69

LN-9268-11.4

N O T E

Figure 40: Installing Atomizer Body
Assembly Onto Atomizer Extension

11/16" wrench for the dump fitting nut. It may
be necessary to use a wrench on the fitting.
Use a 13mm wrench for the 6mm paint fitting
and a 16mm wrench for the dump fitting.

Starting with the tubing at the center most of
the atomizer body, insert the tubing into the
quick disconnect collets. Make sure tubing is
fully inserted. (Reference Figures 41 and 42
for proper tubing locations.)

Install the fiber optic cable to the rear plate by
going through the hole in the solvent/cup wash
manifold. Align the flat on the fiber optic cable
with the set screw and tighten to 10 lbs.- in.
(1.13 Nm) torque.

>Make sure fiber optic cable is flush with face
of rear plate assembly.

Next connect the solvent line from the atomiz-
er body to the solvent/cup wash manifold.
Tighten carefully in place.

Slide mounting ring over atomizer extension,
threaded end facing towards the rear.

Reinstall break-away ring by aligning the four
(4) holes with the dowel pins on the recessed
face of the rear manifold. Reinstall the six (6)
stainless steel screws. Tighten evenly to 15-
20 lbs.- in. (1.69 - 2.26 Nm) torque. If you are
using the optional plastic break-away screws,
tighten evenly to 5 lbs.- in. (.56 Nm) torque.
The break-away ring must lie flat against the
face of the rear manifold.

Special Note:

When replacing the tubing in

the atomizer extension, make sure to slide tub-
ing (76998-04 - Item 53) over the paint line
(A10841-03 - Item 43) before installing nuts

and ferrules onto fittings and tightening. This
tubing is required as an extra dielectric shield
when the high voltage cable is installed.

Advertising