Rma-303 indirect charge - maintenance – Ransburg RMA Indirect A12869 User Manual
Page 64
RMA-303 Indirect Charge - Maintenance
59
LN-9268-11.4
* See Note below.
>When this electrode assembly is used, you
must use the 78442-00 In-Line Resistor As-
sembly for the 74793-XX RansPak cascade
and the 78809-00 ground resistor assembly.
The ground resistor assembly is placed be-
tween the atomizer ground connection and a
true earth ground source.
N O T E
Chart A
Probe Resistance Check
Ring
Type
Part #
Resistance
Reading
Used At
(Location)
8 Probe *
A11343-03
133-147
Megohms
Above 5000 Ft.
W/In-Line Re-
sistor
8 Probe
A11343-02
133-147
Megohms
Sea Level
Figure 14: 78842-00 In-Line
Resistor Assembly
Figure 15: 78809-00 Ground
Resistor Assembly
Figure 16: 78441-00 Ferrule Orientation
Figure 17: Shroud Removal
Figure 18: High Voltage Cable Installation