1. Specifications Check

25

3) From the load ratio LF and the acceleration/deceleration time ratio t

od

that were used to figure out the

duty ratio, read the duty ratio.

e.g.) When the load ratio LF = 80% and the acceleration/deceleration time ratio t

od

= 80%, the

reference for the duty is approximately 75%.

1.2.10 Protection class

RCAW-RA3C/RA3D/RA3R/RA4C/RA4D/RA4R 㧩 IP54

Reference for Operation Duty

Acceleration/Deceleration Time Ratio t

od

About

72 %

Less than 50 %

High Accel/Decel Type

High Accel/Decel Type

High Accel/Decel Type

High Accel/Decel Type