4. Maintenance

75

4.6.2 Replacing the Motor of the Motor Reversing Type: RA3R/RA4R Types

[Items Required for Replacement]

y

Replacement motor unit

y

Allen wrenches

y

Tension gauge (capable of tensioning to 7 kgf or greater)

y

Strong string, looped (or long tie-band)

y

Scale

y

Oil-based marker pen

y

PC or teaching pendant

[Overview of Replacement]

1) Loosen the motor-unit affixing bolts to remove the belt, and replace the motor.

2) Restore the home position.

Affix the rod at a position 2 mm from the mechanical end on the home side, pass the belt, and adjust

the belt to the specified tension.

3) Perform homing using a PC or teaching pendant and check for deviation from the initial home

position.

If there is a deviation, adjust the home offset if you are using an ACON controller. If you are using an

ASEL controller, adjust the home preset.

Replacement motor unit

Z phase ON

position

Mechanical end

Home position

Approx. 2 mm

The countermark on the motor

aligns with this position.

Set by the home offset parameter (ACON) or home preset

parameter (ASEL). (The above value indicates the factory setting.)

1 mm