4. Options

4.2 Extended Cable track

The standard cable track that comes pre-assembled on large nut rotary actuators is used exclusively for
the wirings of the nut rotary actuator and has no space for accommodating any additional wirings the user
may require.
Accordingly, extended cable tracks are provided as options to accommodate user wirings.
The standard cable tracks that come with small and medium types have a space to accommodate user
cables. Refer to the following page.

Model of extended

cable track option

Cable track installation direction

ET1 Standard

ET2 Reversed
ET3

Standard, with home on opposite side

ET4

Reversed, with home on opposite side

Standard cable track specification

Extended cable track specification (optional)

The points to note when storing cables/hoses in an extended cable track (optional) are specified
below:
[1] Provide a minimum clearance of 2 mm between the outer diameter of the cable/hose bundle and

the interior wall of the cable track, and also between the individual cables and hoses.

[2] Use cables/hoses with an outer diameter of

I16.8 or less, and arrange the cables/hoses

horizontally by making sure they don’t cross with one another.

Take note that if the cables/hoses are stored without observing the above precautions, the
cables/hoses will receive an excessive force and their life will become significantly shorter.