4 deviation overflow error (error code: c6b) – IAI America NS User Manual

Page 73

Advertising
background image

59

12. T

roubleshooting

12.4 Deviation Overflow Error (Error Code: C6B)

Faulty controller?

If the problem still persists, contact
IAI.

Replace the controller.

If a replacement controller is
available, swap the controllers
and check the operation.

Deviation overflow error

Excessive

acceleration/deceleration relative

to the load capacity?

Reduce the
acceleration/deceleration.

[1] The connector is not securely

connected.

[2] Loose pins.
[3] Wrong addresses (the motor

and encoder connectors are
connected in reverse).

Broken motor cable?

Replace the motor cable.

Connector wiring error?

Slider contacting any

peripheral equipment?

Remove the contacting object.