10. Notes on Operation

10. Notes on Operation

10.1

Load Applied to the Actuator

x The load specified in the specification table must not be exceeded.

In particular, pay attention to the moments applied to the slider, allowable overhang length and loaded
mass.

x If the actuator is used as the Y-axis in a cantilever X-Y robot, the base becomes vulnerable to

deformation. Accordingly, keep the Ma and Mc moments to one half the rated moment or below. (Refer
to the figure below.)

Small type

SXMS, SXMM, SZMS, SZMM

Allowable load moments

Ma

Mb

Mc

28.4 N

‚m (2.9 kgf‚m)

40.2 N

‚m (4.1 kgfwm)

65.7 N

‚m (6.7 kgfwm)

Allowable overhang lengths

Ma direction

Mb direction

Mc direction

450 mm max.

450 mm max.

450 mm max.

Medium type MXMS, MXMM, MXMXS, MZMS, MZMM

Allowable load moments

Ma

Mb

Mc

69.6 N

‚m (7.1 kgf‚m)

99.0 N

‚m (10.1 kgfwm) 161.7

N

‚m (16.5 kgfwm)

Allowable overhang lengths

Ma direction

Mb direction

Mc direction

600 mm max.

600 mm max.

600 mm max.

Large type

LXMS, LXMM, LXMXS, LZMS, LZMM

Allowable load moments

Ma

Mb

Mc

104.9 N

‚m (10.7 kgf‚m) 149.9

N

‚m (15.3 kgfwm) 248.9

N

‚m (25.4 kgfwm)

Allowable overhang lengths

Ma direction

Mb direction

Mc direction

750 max.

750 max.

750 max.

z The allowable overhang lengths are based on a configuration where the center of gravity of the

installed article is positioned at one half the overhang length.

Application of an excessive load moment may lead to unwanted outcomes such as a shorter service life of
the guide. If the overhang length exceeds the allowable value, vibration may occur or the service life of the
guide may be negatively affected.