26

6SHFL¿FDWLRQV

Model

Unit

MXMXS, horizontal specification

MZMS, vertical

specification

MZMM, vertical

specification

Lead

0

3

0

2

0

3

0

2

Stroke

mm

1600 to 2200

1600 to 2200

510 to 810

300 to 800

Rated thrust

N

170.9

113.9

170.9

170.9

Maximum speed

mm/sec

1200

1800

1000

1000

Rated acceleration

*3

G

0.3

0.3

0.3

0.3

G

0.3

0.3

0.5

0.5

Maximum
acceleration/deceleration

*3

Loading capacity at rated
acceleration

*2

kgf

40

(When used
horizontally)

25

(When used
horizontally)

6

(When used

vertically)

6

(When used

vertically)

40

(When used
horizontally)

25

(When used
horizontally)

3

(When used

vertically)

3

(When used

vertically)

Loading capacity at
maximum acceleration

*2

kgf

Positioning repeatability

mm

r0.01

r0.01

r0.01

r0.01

Ma: 69.6 (7.1)

Ma: 69.6 (7.1)

Ma: 69.6 (7.1)

Ma: 69.6 (7.1)

Mb: 99.0 (10.1)

Mb: 99.0 (10.1)

Mb: 99.0 (10.1)

Mb: 99.0 (10.1)

Load moment

*1

N. m
(kgf cm)

Mc: 161.7 (16.5)

Mc: 161.7 (16.5)

Mc: 81.3 (8.3)

Mc: 81.3 (8.3)

Ma direction:

600 max.

Ma direction:

600 max.

Ma direction:

600 max.

Ma direction:

600 max.

Overhang load length

mm

Mb/Mc directions:

600 max.

Mb/Mc directions:

600 max.

Mb/Mc directions:

600 max.

Mb/Mc directions:

600 max.

*1

Based on an acceleration of 0.3 G and the maximum speed.

*2

The maximum speed is assumed.

*3

The table below shows the relationship of acceleration/deceleration and loading capacity.
These values are not guaranteed and should be used only as a guide.
Even when the acceleration is equal to or below the rated acceleration, the loading capacity remains the same
as the value at the rated acceleration.
As for actuator types with mid-support, the maximum acceleration is the same as the rated acceleration.
Accordingly, the loading capacity at the maximum acceleration corresponds to the loading capacity at the rated
acceleration.

Loading capacity by acceleration (kg)

Type

Lead

Maximum speed

0.3G

0.4G

0.5G

MZMS

MXMXS

MZMM

20 mm

1000 mm/sec

6

30 mm

1800 mm/sec

20 mm

1200 mm/sec

4

40

н
н

н

н

25

3

Caution:

x Use each actuator by observing its maximum speed.
x Take note that resonance may still occur at speeds below the applicable limit specified

above, depending on the installation condition or operating conditions.

x Resonance of the ball screw shaft may increase the noise level or cause vibration,

resulting in a shorter service life of the machine.

x If each actuator is used independently, write a program conforming to the maximum

speed of the actuator (refer to the table above). If multiple actuators are used in a
synchronized operation, write a program conforming to the lowest of the maximum
speeds applicable to all synchronized actuators.

x In either way, always check the maximum speed of each applicable actuator when writing

a program.