5. Precautions for Use

(2) CP operation

To operate the robot at the maximum acceleration, provide a stopping period of three seconds or

more after each acceleration/deceleration.

Start from the appropriate reference range for the continuous operation setting, and then gradually

raise the value for the purpose of adjustment.

If an overload error occurs, lower the acceleration setting as appropriate or provide an appropriate

stopping time following each acceleration/deceleration.

Depending on the position of the vertical axis, the robot may generate vibration when axis 1, axis 2

or the rotational axis turns. If vibration occurs, lower the acceleration as appropriate.

To move the robot horizontally at high speed, keep the vertical axis as close as possible to the top

position. If the vertical axis is operated at the bottom position, the ball screw spline shaft will bend

and the vertical axis will be disabled.

Be careful that the moment of inertia of axis 4 does not exceed the permissible value. (Refer to 5.3,

“Carrying Load.”)

The carrying load indicates a load above the rotational center of axis 4.

Operate the robot by using an appropriate acceleration coefficient as determined by the mass of

the tip. Failure to do so may cause the drive part to wear prematurely or may result in damage or

vibration.

IX-HNN50/60

IX-INN50/60

Reference acceleration/deceleration

settings for CP operation

A

cce

le

ra

tio

n (G)

Carrying load mass (kg)

1.0

0.5

0

0 5

10

A

cce

le

ra

tio

n (G)

Carrying load mass (kg)

1.0

0.5

0

0 5 10 15 20

IX-HNN70/80

IX-INN70/80

Reference acceleration/deceleration

settings for CP operation

Reference range of

maximum setting

Reference range of

maximum setting

Reference range for

continuous operation setting

Reference range for

continuous operation setting