Caution, 2 removing the cover – IAI America IX-INN8040 User Manual

Page 39

Advertising
background image

33

6. Inspection/Maintenance

6.2.2 Removing the Cover

(1) With arms 1 and 2 extended as illustrated below, press the brake-release switch [1] to release the

brake and then push down the vertical axis until the stopper contacts the pulley. (For the inverse

specification, pull up the vertical axis until the stopper contacts the pulley.)

(2) Remove the countersunk head screws [2], [3] and [4] (four pieces each), in that order.

(3) Remove all connectors (UA, UB, BK and LED) and air tubes (four pieces) from the back of the panel.

(4) Move the cover to the position shown in the photograph.

Remove the four outer screws for the countersunk head screws (4).

Do not remove the M/PG connectors at the rotary joint, since it will necessitate an absolute reset.

The cover will not detach completely, since the M/PG connectors are still connected. Do not pull

the cover forcibly.

[4] 4 - M3 x 10 (countersunk head screw)

Panel

[1] Brake-release switch

[2] 4 - M3 x 8 (countersunk head screw)

[3] 4 - M3 x 10 (countersunk head screw)

Caution

Mechanical stopper for vertical axis

Advertising