67 7. speci fi cations – IAI America IX-INN8040 User Manual

Page 73

Advertising
background image

67

7. Speci

fi cations

IX-HNN70 (Arm Length 700, Ceiling-mount Specification)

Item

Specifications

Type

IX-HNN70-**L-T1

Degree of freedom

Four degrees of freedom

Overall arm length

700

Arm 1 length

350

Arm 2 length

mm

350

Axis 1 (arm 1)

AC servo motor + Speed reducer

Axis 2 (arm 2)

AC servo motor + Speed reducer

Axis 3 (vertical axis)

AC servo motor with brake + Belt + Ball-screw spline

Drive method

Axis 4 (rotational axis)

AC servo motor with brake + Speed reducer + Belt + Spline

Axis 1 (arm 1)

750

Axis 2 (arm 2)

400

Axis 3 (vertical axis)

400

Motor capacity

Axis 4 (rotational axis)

W

200

Axis 1 (arm 1)

125

Axis 2 (arm 2)

degree

145

Axis 3 (vertical axis) (*1)

mm

200 (Optional: 400)

Movement range

Axis 4 (rotational axis)

degree

360

Axis 1 + Axis 2 (maximum composite speed)

6597

Axis 3 (vertical axis)

mm/sec

1583

Maximum

operating speed

(*2)

Axis 4 (rotational axis)

degree/sec

1200

Axis 1 + Axis 2

0.015

Axis 3 (vertical axis)

mm

0.010

Positioning

repeatability (*3)

Axis 4 (rotational axis)

degree

0.005

Cycle time (*4)

0.50

Rated

5

Load capacity

Maximum

kg

20

Dynamic (*8)

265 (27.0)

Push-in thrust of

axis 3 (vertical axis)

Static (*9)

N (kgf)

188 (19.1)

Permissible moment of inertia (*5)

kgm

2

0.1

Permissible load

on axis 4

Permissible torque

Nm (kgfcm)

6.7 (68.3)

Permissible tool diameter (*6)

mm

100

Origin detection

Absolute

User wiring

D-sub 25-pin connector with 25-core AWG26 shielded cable (socket)

Alarm indicator (*7)

One small, red LED indicator (rated voltage: 24 V)

User piping

Two air tubes (outer diameter: 6, inner diameter: 4) (normal service pressure: 0.8 MPa)

Two air tubes (outer diameter: 4, inner diameter: 2.5) (normal service pressure: 0.8 MPa)